Industrial EthernetRESoluCOM French

Home| Utility | Go Down

Anybus-PCI

Anybus-PCI

Network Interface Cards with PCI bus

 

 


 

 

 

 

 

 

Concept of Anybus-PCI

Powerful Master and Slave PC-Interfaces and software supporting Profibus, DeviceNet, AS-Interface, EtherNet/IP & Profinet. Based on proven embedded Anybus technology.
The Anybus-PCI cards are based on the proven Anybus technology, implemented in over 300,000 industrial applications worldwide.

Our partner HMS has developed this PCI solution based on the high performance / high volume embedded Anybus Master and Slave interface range. As a result HMS can offer a very competitively priced PCI solution with the high performance and interchangeability of the Anybus range
.


 


 

 

 

 

 

 

Key Features

    3,3 & 5V support (Universal keyed add-in)
    Competitively priced - high performance
    Easy to install Plug & Play interface
    Common API used for all Anybus- PCI’s - one driver for all buses
    33 Mhz PCI bus clock
    On-board microprocessor
    Supports Interrupt/Polling
    2kB Dual Port RAM (4kB Profibus DPV1 Master)
    256 byte mailbox interface extends up to 2048 bytes for parameter data
    Galvanically isolated fieldbus interface
    Free OPC Server
    CoDeSys support (Profibus Cards)
    Drivers & API supporting Win 98/ ME/NT/2000/XP
    SDK included (CD, Drivers, DLL’s, Sample Code)
    Anybus NetTool configuration software for Profibus & DeviceNet network setup
    Tested and verified for Fieldbus/Ethernet conformance
Return to the top of the page

 


 

 

 

 

 

 

Technical Overview

 

Powerful Master and Slave PC-Interfaces and softare supporting Profibus, DeviceNet and AS-Interface. Based on proven Anybus technology.

3.3 or 5V

The Anybus-PCI range is a solution operating at both 3,3 & 5V that offers Master & Slave versions for Profibus and DeviceNet and a Master version for AS-Interface.


Common API
The Application Programming Interface (API) used on the PCI card simplifies development drastically by taking care of low level functions such as handshaking and providing easy to use functions for common Anybus related tasks such as mailbox handling. The API provides a plug and play interface compatible with all available Anybus Master and Slave interfaces.

2Kbyte Dual Port Ram
The Anybus-PCI interface contains a Dual Port Ram that allows the module and the host device to independently address different memory areas. The PCI cards also contain an on-board microprocessor, fieldbus ASIC, DC/DC converters, opto couplers and line drivers in order to fulfil all requirements for each fieldbus.

Additional Mailbox Interface
Provided additionally through the Anybus module is a “Mailbox interface” which allows the user to take advantage of all features in the Anybus-S module and the specific fieldbus network. Through this interface it is possible to customize the PCI card to be more device specific and present itself on the network as a custom product.

Windows Driver
The source code is easily written using the provided sample codes and library files. Example codes are available in C++, Visual Basic and Delphi.

Software Development Kit
An SDK is available for customers using the cards in non-Windows operating systems. C-code of Windows hardware drivers will be provided upon request.

OPC Server & CoDeSys Driver
HMS provides a free OPC Server for its line of PCI Interface cards, Anybus-PCI. Together, the card and the OPC Server, allow users of software applications, such as Scada systems or HMI’s (OPC Clients), to access real-time data from devices connected to an Industrial Network.

The OPC Server supports Data Access (DA) 3.0 and includes a Tag Editor. Included also is a driver for CoDeSysCoDeSys Realtime Runtime System for Windows NT/2000/XP from 3S.

Return to the top of the page

 


 

 

 

 

 

 

Specifications

  TECHNICAL SPECIFICATIONS
Size:
    100 x 120 x 22mm (L x W x H) 3.94 x 4.72 x 0.87” (L x W x H )
Power Supply:
    3.3 & 5 Volt, 600mA VDC
Temperature:
    Operating +0°C to + 55°C
Env Conformance:
    RoHS Conformance pending
EMC Certification:
    CE marked, UL & cUL conformance
Conformance:
    Tested and verified for fieldbus conformance

 

 

 

 

 


 

 

 

 

 

 

 

 

Questions & Answers on Anybus-PCI

Read the most common questions about the Anybus-PCI Cards & Software.

Q: Is the Anybus PCI card compatible with all PCs?
A: The card is a “short PCI” card supporting both 5 volt and 3,3 volt operation (“Universal keyed”). This makes the card compatible with most PCs with a PCI slot.

Q: When I install the Anybus PCI card I need to select "transport provider", what’s that?
A: The drivers from HMS are designed to be modular. The "transport provider" is a software piece that route data between the Anybus API and the low level drivers of the PCI card.

Q: HMS supplies drivers for Windows environment, but I am using WxWorks, can I use the Anybus PCI card?
A: HMS does not provide standard drivers for WxWorks, but for OEMs we provide the source code so the OEM-can modify this to his OS environment or other specific needs. We have “Anybus Solution Provider” (ASP) partners who offer design custom drivers. RESoluCOM is an ASP.

Q: If I want to use the Profibus Master, how do I configure the Profibus Slaves connected to the Master?
A: You need the HMS Software “NetTool for Profibus ” which is our new Windows based configuration software. A free download is available on www.anybus.com (free version is limited to connect two slaves only)

Q: I am using RS Networks software from Rockwell Automation, can I configure the DeviceNet Scanner and DevcieNet Adapter from this tool?
A: Yes, you can configure the DevcieNet cards from RS-Networx, you might need the KFD device from Rockwell to connect the DeviceNet network.


Q: We design an embedded controller based on the PLC kernel from Smart Software Solutions (3S), can we use Anybus PCI?
A: Yes, both the Anybus PCI card and the embedded Anybus modules are supported by the 3S software (from 3S version 2.3 ; service pack 3)

Return to the top of the page

 


 

 

 

 

 

 

 

Selection Guide Anybus-PCI

Profibus-DPV1 master
AB3502

DeviceNet Scanner
AB3504

AS-Interface master
AB3505
EtherNet/IP Scanner
AB3507

• Complete Profibus Class 1 & Class 2 master according to IEC 61158
• Up to 125 DP/DPV1 slaves can be connected
• Up to 1536 bytes input & 1536 bytes output data
• Supports Profibus baud rates up to 12 Mbit/s
• RS-485 optically isolated Profibus interface
with on-board DC/DC converter
• Configuration via Anybus NetTool Windows based configuration software

• Complete DeviceNet 2.0 scanner
implementation according to ODVA
• Group 2 Client/Server / UCMM support
• Baud rates: 125-500 kbit/s
• Optically isolated DeviceNet interface
• Up to 512 bytes input & 512 bytes output data.
• Controls up to 63 DeviceNet slave/Adapters
• Supports FLASH field upgrades
• Configuration via Anybus NetTool or
RSNetworx

• Complete AS-Interface master supporting version 2.1 and also backwards compatible with version 2.0
• Manages control of up to 62 AS-Interface slaves.
• Up to 248 digital inputs & 186 digital outputs
• Up to 124 (16 bit) analog values
• Optically isolated interface.
• Full extended master M1E
• Supports auto-configuration or configuration via RS232 using standard Windows Hyper-terminal program on your PC

• Complete EtherNet/IP master/Scanner interface
• Dual Port (DPRAM) parallel interface
• Ethernet settings configurable through a
inbuilt web server or with on-board DIP switches
• EtherNet/IP level 4 I/O Client - ODVA Certified
• Transformer isolated Ethernet interface
• IT functions Dynamic Web, and FTP server and Email client

Profibus-DPV1 slave
AB3501

DeviceNet Adapter
AB3503
Profinet
AB3509
EtherNet/IP Adapter
AB3506

• Complete Profibus-DPV1 slave functionality
according to Extensions of IEC 61158
• Up to 244 bytes input & 244 bytes output
• Supports PA baud rate 45.45 kbit/s
• Supports Class 1 and Class 2 services
• Automatic baudrate detection (9,6 Kbit/s -
12 Mbit/s)
• RS-485 optically isolated Profibus interface
with on-board DC/DC converter

• Complete DeviceNet 2.0 adapter
implementation according to ODVA, Group 2 only server
• DIP switch select baud rate and MACID
• Baud rate: 125-500 kbit/s
• Optically isolated DeviceNet interface
• Up to 512 bytes input & 512 bytes output data

• Complete Profinet-IO device functionality
• Max.1300 bytes of input and 1300 bytes output data
• 100 Mbit full duplex transmission
• RJ45 Connector
• Powerful 32 Bit Processor for short cycle times
• GSD file for easy config
• IT functions Dynamic Web, and FTP server and Email client

• Complete EtherNet/IP slave/adapter interface
• IP address settings configurable through
on-board DIP switches, Webpage, DCP or DHCP
• Baud rate: 10/100 MBit/s
• EtherNet/IP level 2 I/O Server
• Transformer isolated Ethernet interface
• IT functions Dynamic Web, and FTP server and Email client

Modbus-TCP
AB3508
FL-Net
AB3510
   

• Complete Modbus/TCP server functionality
• IP address settings configurable through on-board DIP switches, Webpage, DCP or DHCP
• Baud rate: 10/100 MBit/s
• Transformer isolated Ethernet interface
• IT functions Dynamic Web, and FTP server and Email client

• Complete FL-Net server functionality
• Supports shielded (STP) & unshielded (UTP) cables
• FL-NET Class 1 node
• Customizable identity/profile information
• Up to 512 bytes cyclical I/O in each direction
• Dual Port (DPRAM) parallel interface
• Transformer isolated Ethernet interface

   
Customized versions for specific requirements available on request - Contact us
Return to the top of the page

 


 

 

 

 

 

 

 

 

Document Downloads Anybus-PCI

General files for Anybus-PCI

 File Name  Version Size (KB) 
 PDF Document API Reference Manual 1.10 404,79 kb
 PDF Document Anybus-S Design Guide 2.00 1 571,02 kb
 PDF Document Brochure/Shortform (English) 2006 1 162,52 kb
 
Return to the top of the page

 

About Us | Site Map | Privacy Policy | Contact Us |