Ethernet DDE Servers (on off the shelves ports)

- Overview Ethernet DDE Servers (on standard ports)
- Key Featuress Ethernet DDE Servers
- Selection Guide for Ethernet DDE Servers
Overview Ethernet DDE Servers (INAT)
The INAT DDE Servers Ethernet provide access to Siemens PLCs, Allen-Bradley PLCs, INAT CPs, Mitsubishi PLCs and Modbus on TCP Interfaces via TCP/IP, RFC1006 and H1
Six DDE Servers are available, each with a different range of supported protocols. Depending on the supported transport protocols and application protocols, communication is possible with Siemens S5/S7 PLCs, Allen-Bradley PLCs, Mitsubishi PLCs and devices with Modbus on TCP interface.
For all INAT Ethernet DDE Servers one installation file is used. At the end of the installation you are asked which Server Type you would like to use. With the next start of the DDE Server it runs with the selected protocol range.
The Server Type may be changed at any time. This provides the opportunity to test the functional range of the diverse Server Types without installing another software.
Note: If you have already installed and licenced a server and change the server type your licence expires. You need a new licence confirm code or a new dongle!
Key Features Ethernet DDE Servers (INAT)
| Quick and secure coupling with visualizations, data bases and control systems with DDE- and SuiteLink interface | |
| Coupling to Wonderware Intouch via SuiteLink | |
| NEW: High Performance Protocol provides dynamic throughput organization | |
| NEW: Routing via S7 subnetzs Access S7 PLCs in Profibus subnets or MPI subnets | |
| No limitation of number of connections, no limitation of number of tags | |
| Access to Ethernet devices from INAT, Siemens, Rockwell Automation, Mitsubishi, Wago, Schneider | |
| Runs as service or as application | |
| Easy Import of Step 7 symbolic names directly from the Step 7 project | |
| Send / Receive for communications via the socket interface (raw data) | |
| Easy implementation with symbolic addressing (Alias Browsing) | |
| Static and dynamic tags | |
| Standards: SuiteLink, DDE, FastDDE, CF-Text | |
| High reliability, requires less system ressources |
Selection Guide

| All-in-One DDE Server with maximum range of supported protocols | |
| For INAT and Siemens CPs, Allen-Bradley PLC-5 controllers, Mitsubishi Melsec-Q controllers, several Modbus on TCP coupler / controllers, Including ISO on TCP (RFC1006) and INAT H1 driver | |
| Communicates via TCP/IP, ISO on TCP (RFC1006), TCP/IP with PLC Header, ISO (H1) | |
Order Code for Single user license: |
100-3050-01 |
Order Code for Single user license incl. USB dongle: |
100-3050-20 |
Order Coder for Upgrade: |
100-3050-Upg |
Order Code for Upgrade incl. USB dongle: |
100-3050-Dgl |
| For Siemens and INAT CPs, Allen-Bradley PLC-5 controllers, Mitsubishi Melsec-Q controllers, several Modbus on TCP coupler / controllers, Including ISO on TCP (RFC1006) | |
| Communicates via TCP/IP and RFC1006 (no H1) | |
Order Code for Single user license: |
100-3070-01 |
Order Code for Single user license incl. USB dongle: |
100-3070-20 |
Order Code for Upgrade: |
100-3070-Upg |
Order Code for Upgrade incl. USB dongle: |
100-3070-Dgl |
| For INAT CPs and several Modbus on TCP coupler / controllers | |
| Communicates via TCP/IP (no RFC1006, no H1) | |
Order Code for Single user license: |
100-3080-01 |
Order Code for Single user license incl. USB dongle: |
100-3080-20 |
Order Code for Upgrade: |
100-3080-Upg |
Order Code for Upgrade incl. USB dongle: |
100-3080-Dgl |
| For Siemens and INAT CPs | |
| Communicates via H1 | |
Order Code for Single user license: |
100-3060-01 |
Order Code for Single user license incl. USB dongle: |
100-3060-20 |
Order Code for Upgrade: |
100-3060-Upg |
Order Code for Upgrade incl. USB dongle: |
100-3060-Dgl |
| For several Modbus on TCP coupler / controllers, INAT CPs (ONLY Modbus and Send / Receive communications!) | |
| Communicates via TCP/IP | |
Order Code for Single user license: |
100-3090-01 |
Order Code for Single user license incl. USB dongle: |
100-3090-20 |
Order Code for Upgrade: |
100-3090-Upg |
Order Code for Upgrade incl. USB dongle: |
100-3090-Dgl |
| For Mitsubishi Melsec-Q Series PLCs | |
| Communicates via TCP/IP | |
Order Code for Single user license: |
100-3095-01 |
Order Code for Single user license incl. USB dongle: |
100-3095-20 |
