| Technology |
|
IEEE802.3 10Base-T
IEEE802.3u 100Base-TX
IEEE802.3x flow control
|
|
|
Store and forward technology and with 3.2Gbps switch bandwidth |
|
| Aggregate System Throughput |
|
|
| Interface |
|
5 x 10/100 Base-TX with Auto MDI/MDI-X function |
|
|
10/100 Base-TX: RJ-45
Power / Relay: 4-pin terminal block |
|
|
CAT-3, CAT-4, CAT-5 unshielded twisted pair or shielded twisted
pair cable. The Link distance is 100 meters in maximum |
|
|
DIP 1~5: Enable or disable port link down alarm from port 1 to port 5
On: Enable port link down alarm
Off: Disable port link down alarm |
|
|
System: Power (green), Fault (red on)
RJ-45 port: 100Mbps Link (green on)/Activity(green flashing),
10Mbps Link (yellow on)/Activity(yellow flashing) |
|
| Power Requirements |
|
2 pins terminal block for power input.
DC 24V(18~32V)with reverse polarity protection.AC 18~27V, 47~63Hz |
|
|
|
| Mechanical |
|
|
|
IP-31 protection, aluminum case |
|
|
111.8mm(H) x 30mm (W) x 98.2mm (D) ( with DIN rail clip)
111.8mm(H) x 30mm (W) x 89.4mm (D) ( without DIN rail clip) |
|
|
372g with package
290g without package |
|
| Environmental |
|
|
|
5% to 95% (Non-condensing) |
|
|
|
|
|
| Regulatory Approvals |
|
|
|
EN61000-4-2: 6Kv Contact, 8Kv Air, ESD contact indirect 6kv
EN61000-4-3: 10V/m, 80 MHz - 1 GHz, AM 1 KHz, 80% modulation,
10V/m, 0.9 - 1.8 GHz, FM 200 Hz, 50% modulation
EN61000-4-4: PWR Supply Lines:+/- 2KV,Communication Lines:+/- 2KV
EN61000-4-5: 2KV on power line (L-N), 4KV on power line (L-PE, N-PE), 1.2uS Tr/ 50uS Th
EN61000-4-6: PWR Supply Lines:10 Vrms, 150 KHz - 80 MHz;AM 1 KHz,
80% modulation; Communication Lines:10 Vrms, 150 KHz - 80 MHz;AM 1 KHz,80% modulation;Relay:10 Vrms, 150 KHz - 80 MHz;AM 1 KHz, 80% modulation
EN61000-4-8: 50Hz, 3A/m
EN61000-4-11: 30% 10 ms,60% 100 ms, > 95% 5000 ms |
|
|
|
|
IEC60068-2-27 shock: 50 g, 11ms, 4g, +/- X, +/- Y, +/- Z |
|
|
IEC60068-2-32 free fall:90 cm, 1 corner, 3 edges, 6 faces |
|
|
IEC60068-2-6 vibration: 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz,90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz,10 cycles, 1 octave/min |
|
|
|
| Technology |
|
IEEE802.3 10Base-T
IEEE802.3u 100Base-TX
IEEE802.3u 100Base-FX
IEEE802.3x flow control
|
|
|
Store and forward technology and with 3.2Gbps switch bandwidth |
|
| Aggregate System Throughput |
|
|
| Interface |
|
4 x 10/100 Base-TX with Auto MDI/MDI-X function, 1 x 100Base-FX |
|
|
10/100 Base-TX: RJ-45
100Base-FX: Duplex SC
Power / Relay: 4-pin terminal block |
|
|
RJ-45 connector: supports CAT-3, CAT-4, CAT-5 unshielded twisted pair
or shielded twisted pair cable. The link distance is maximum 100 meters.
SC connector: supports multi-mode or single-mode optical fiber.
Multi-mode fiber: 50/125um or 62.5/125um, max. distance 2KM
Single-mode fiber: 8/125um, 9/125um or 10/125 um, max. distance 30KM |
|
|
JetNet2005f-m, Multi-mode: 2KM max. distance
Wave-length: 1310nm
Min Tx Power:-19dBm
Max Tx Power:-14dBm
Min Rx Sensitivity:-30dBm
Link budget:11dBm
JetNet2005f-s, Single-mode: 30KM max. distance
Wave-length:1310nm
Max Tx Power:-8dBm
Min Tx Power:-15dBm
Min Rx Sensitivity:-34dBm
Link budget:19dBm |
|
|
DIP 1~5: Enable or disable port link down
alarm for copper port 1~4, fiber port 5
On: Enable port link down alarm
Off: Disable port link down alarm |
|
|
System: Power (green), Fault (red)
RJ-45 port: 100Mbps Link (green on)/Activity(green blinking)
10Mbps Link (yellow on)/Activity(yellow blinking)
Fiber port: Link/Activity(Green) |
|
| Power Requirements |
|
2 pins terminal block for power input.
DC 24V(12~48V)with reverse polarity protection.AC 18~36V, 47~63Hz |
|
|
|
| Mechanical |
|
|
|
IP-31 protection, aluminum case |
|
|
111.8mm(H) x 30mm (W) x 98.2mm (D) ( with DIN rail clip)
111.8mm(H) x 30mm (W) x 89.4mm (D) ( without DIN rail clip) |
|
|
377g with package
295g without package |
|
| Environmental |
|
|
|
0% to 90% (Non-condensing) |
|
|
|
|
|
| Regulatory Approvals |
|
|
|
EN61000-4-2: 6Kv Contact, 8Kv Air, ESD contact indirect 6kv
EN61000-4-3: 10V/m, 80 MHz - 1 GHz, AM 1 KHz, 80% modulation,10V/m,
0.9 - 1.8 GHz, FM 200 Hz, 50% modulation
EN61000-4-4: PWR Supply Lines:+/- 2KV,Communication Lines:+/- 2KV
EN61000-4-5: 2KV on power line (L-N), 4KV on power line (L-PE, N-PE), 1.2uS Tr/ 50uS Th
EN61000-4-6: PWR Supply Lines:10 Vrms, 150 KHz - 80 MHz;AM 1 KHz,
80% modulation; Communication Lines:10 Vrms, 150 KHz - 80 MHz;AM 1 KHz,80% modulation;Relay:10 Vrms, 150 KHz - 80 MHz;AM 1 KHz, 80% modulation
EN61000-4-8: 50Hz, 3A/m
EN61000-4-11: 30% 10 ms,60% 100 ms, > 95% 5000 ms |
|
|
|
|
IEC60068-2-27 shock: 50 g, 11ms, 4g, +/- X, +/- Y, +/- Z |
|
|
IEC60068-2-32 free fall:90 cm, 1 corner, 3 edges, 6 faces |
|
|
IEC60068-2-6 vibration: 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz,90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz,10 cycles, 1 octave/min |
|
|
|